Specifications

11
9RLQ 12RLQ
9,000 12,000
3,600~12,000
12,000
3,800~14,500
16,000
3,000~18,000
11.0
3,100~21,000
10.55
21.0 21.0
13.4/14.5 12.5/12.8
14~115 (-10~46)
5~75 (-15~24)
2.7 (1.3)
14~115 (-10~46)
5~75 (-15~24)
3.8 (1.8)
208-230/60/1 208-230/60/1
20 20
350 (595) 374 (635)
280 (476) 300 (510)
224 (381) 240 (408)
180 (306) 192 (326)
42/42 (Clg/Htg) 43/43 (Clg/Htg)
37/37 (Clg/Htg) 37/37 (Clg/Htg)
31/30 (Clg/Htg) 31/30 (Clg/Htg)
22/22 (Clg/Htg) 22/22 (Clg/Htg)
760/680 760/680
47/48 (Clg/Htg) 47/49 (Clg/Htg)
3.2/6.0 4.5/7.0
3.9/8.5 5.7/10.0
0.67/1.2 0.96/1.5
0.83/1.8 1.25/2.14
4 + Auto 4 + Auto
Manual Manual
Automatic Automatic
Washable Washable
Yes Yes
Flare Flare
66 (20) 66 (20)
49 (15) 49 (15)
Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4
21 (9.5) 77 (35) 21 (9.5) 82 (37)
11-1/8 21-1/4 11-1/8 21-1/4
283 540 283 540
31-1/8 31-1/8 31-1/8 31-1/8
790 790 790 790
9-1/16 11-7/16 9-1/16 11-7/16
230 290 230 290
R410A R410A
Nominal Cooling BTU/h
Min.~Max. Cooling BTU/h
Nominal Heating BTU/h
Min.~Max. Heating BTU/h
HSPF BTU/hW
SEER BTU/hW
EER Clg/Htg
Clg. Operating Range °F(°C)
Htg. Operating Range °F(°C)
Moisture Removal
Pt./h(l/h)
Voltage/Frequency/Phase
Recommended Fuse Size
(A)
Air Circ. C.F.M. (m
3
/h): Hi
Medium
Low
Quiet
Noise Level
dB(A): Hi
Medium
Low
Quiet
Outdoor Fan Speed
RPM Clg/Htg
Outdoor Noise Level dB(A)
Current Rated/Max (A): Cooling
Heating
Power Use
Rated/Max (kw): Cooling
Heating
Fan Speeds Stage
Air Direction: Horizontal
Vertical
Air Filter
Plasma Filter
Connection Method
Combined Max. Lgth
Ft (m)
Max. Vertical Diff. Ft (m)
Conn. Pipe Diameter Inch
Net Weight lbs. (kg)
Dimensions: Height Inch
mm
Width Inch
mm
Depth Inch
mm
Refrigerant
21-SEER
21-SEER Wall Mounted 9,000 and 12,000 BTU Systems
SUPER ENERGY EFFICIENCIES
SYSTEMS 9RLQ, 12RLQ
These systems are true energy misers with a seasonal
energy efficiency rating of 21-SEER. These cooling only
and heat pump systems are over 110% more efficient than
older 10-SEER models. Fujitsu, the industry leader in energy
efficient ductless mini-splits, uses variable speed inverter
technology to help achieve some of the highest SEER
equipment available.
Function
Applications
The high efficiency of these systems helps them pay for
themselves by slashing electrical costs. Strong, quiet and
efficient DC motors are used both indoors and outdoors.
High performance fan blades, condensers and evaporators
combined with variable speed inverter-driven compressors
makes for unmatched performance. Variable speed
compressors automatically adjust to fluctuating room capacity
requirements.
Indoor
ASU9RLQ
Outdoor
AOU9RLQ
Indoor
ASU12RLQ
Outdoor
AOU12RLQ
Standard Features
Wireless Remote Control
Plasma Filter
Sleep Timer
24 Hour Timer
Dry Mode
Auto Louver: Up/ Down
Auto Mode
Quiet Mode
Auto Restart/Reset
Auto Changeover
Low Ambient
Cold Prevention
Optional Remote
Weekly Timer
Full Function Wired Remote
Child Lock Capable
Please Note: Due to the use of inverter, system is now 208-230 single phase.
Note: Figures are based on 230 Volts.
UTB-UUB
Heat Pump Heat Pump
6-26-FG2000 20 pgr.qxd 4/12/06 12:47 PM Page 11