6-26-FG2000 20 pgr.qxd 3/3/06 4:17 PM Page 1 2006 PRODUCT LINE For over 30 years, we have been making the hottest places cool and the coolest places more comfortable.
6-26-FG2000 20 pgr.qxd 3/2/06 3:12 PM Page 2 The intelligent ch at play... WHO IS FUJITSU? Engineering Excellence Fujitsu’s innovation drives the success of the Halcyon line. Our manufacturing facilities have met ISO9001 and ISO14001 international standards that assure quality and reliability. These products have been designed to provide zoned comfort for residential and commercial applications.
6-26-FG2000 20 pgr.qxd 3/2/06 3:12 PM Page 3 nt choice in comfort or work. Global Production Comfort Today and Tomorrow With global sales approaching nearly 3 million units a year, we have produced and shipped air conditioning systems throughout the world to make the hottest places cool and the coolest places more comfortable. Halcyon by Fujitsu is a new way to think about air conditioning.
6-26-FG2000 20 pgr.qxd 3/2/06 3:13 PM Page 4 Fujitsu, the W.I.S.E.R. choice in Warranty Indoor Air Quality Size 100% increase in parts warranty to 2-years, 20% increase in compressor warranty to 6-years. Better indoor air quality with electronic plasma filtration that collects dust, cigarette smoke and pollen, as well as absorbs odors.
6-26-FG2000 20 pgr.qxd 3/2/06 3:13 PM Page 5 ce in ductless comfort. ctless with aller up to mini-splits features, than prior 39%. Efficiency R410A Fujitsu’s inverter-driven systems are up to 110% more efficient than prior models. Increased efficiencies mean lower utility costs. All systems use environmentally friendly R410A refrigerant designed to prevent the depletion of the ozone layer which protects us from the harmful rays of the sun.
-26-FG2000 20 pgr.qxd 3/2/06 3:16 PM Page 6 How Does a Mini-Split Work? Quiet Operation Ductless air conditioners are comprised of an indoor and outdoor unit, which allows for a peaceful inside environment by enabling the contractor to install louder components like compressors and motors outdoors. Easy Installation Copper tubing running through a small 3 to 4-inch opening in the wall or ceiling easily connects the indoor and outdoor units.
6-26-FG2000 20 pgr.qxd 3/8/06 12:19 PM Page 7 What is a Heat Pump? An electric heater converts electricity directly to heat, and if we assume that the heat loss is zero, the output from one kilowatt input is one kilowatt or 3,400 BTU and the EER is 3.4. A device that acts as an air conditioner in the summer and as a heater in the winter providing heating and cooling to homes and businesses in one system.
6-26-FG2000 20 pgr.qxd 3/2/06 3:17 PM Page 8 9RLQ 12CQ 12RQ 12RLQ 18CL 18RL 24CL 24RL 30CLX 36CLX 18RULX 24RULX 36RSLX 18RCLX 24RCLX 36RCLX 42RCLX 24RMLQ 14 14 21 13 13 21 19 19 18 18 15 15 16 15 14 16 15 14 15 16* 15* - 8.2 11 - 8.2 11 - 10 - 10 - - Available only with optional wired remote controller. * SEER/HSPF varies based on mix of indoor units selected. 8.5 8.5 8.5 8.5 8.5 8.5 8.
6-26-FG2000 20 pgr.qxd 3/2/06 3:18 PM Page 9 SEER Auto Changeover Seasonal Energy Efficiency Rating. Used to express the efficiency of an AC or Heat Pump. The higher the rating the more efficient. Provides functional change from cooling to heating or viceversa automatically depending on set temperature. Operating range is ±4°F relative to the set temperature. HSPF Low Ambient Heating Seasonal Performance Factor, measures the efficiency of heating portion of your heat pump.
6-26-FG2000 20 pgr.qxd 3/2/06 3:18 PM Page 10 Wall Mounted 9,000 and 12,000 BTU Systems IAQ ELECTRONIC PLASMA FILTER SYSTEMS 9CQ, 9RQ, 12CQ, 12RQ 9CQ 12CQ 9RQ 12RQ Cooling Only Cooling Only Heat Pump Heat Pump Nominal Cooling BTU/h 9,700 12,300 9,700 12,300 Nominal Heating BTU/h - - 9,600 12,800 HSPF BTU/hW - - 8.2 8.2 SEER BTU/hW 14.3 13.5 14.3 13.7 EER Clg/Htg 11.8 11.6 11.8/13.9 11.5/12.9 Clg.
6-26-FG2000 20 pgr.qxd 4/12/06 12:47 PM Page 11 21-SEER Wall Mounted 9,000 and 12,000 BTU Systems Nominal Cooling BTU/h 9RLQ 12RLQ Heat Pump Heat Pump 9,000 12,000 SUPER ENERGY EFFICIENCIES SYSTEMS 9RLQ, 12RLQ Min.~Max. Cooling BTU/h 3,600~12,000 3,800~14,500 Nominal Heating BTU/h 12,000 16,000 Min.~Max. Heating BTU/h 3,000~18,000 3,100~21,000 HSPF BTU/hW 11.0 SEER BTU/hW 21.0 21.0 13.4/14.5 12.5/12.8 EER Clg/Htg 10.55 21-SEER Clg.
6-26-FG2000 20 pgr.qxd 4/12/06 12:48 PM Page 12 Wall Mounted 18,000 BTU Systems ENGINEERING SOPHISTICATION SYSTEMS 18CL, 18RL Nominal Cooling BTU/h 18CL 18RL Cooling Only Heat Pump 18,000 Min.~Max. Cooling BTU/h 5,500~19,000 Nominal Heating BTU/h - 21,600 Min.~Max. Heating BTU/h - 4,600~29,000 HSPF BTU/hW - 10.0 SEER BTU/hW 19.0 19.0 EER Clg/Htg 10.4 10.4/11.2 Clg. Operating Range °F(°C) 14~115 (-10~46) 14~115 (-10~46) 19-SEER Htg.
6-26-FG2000 20 pgr.qxd 4/12/06 12:48 PM Page 13 Wall Mounted 24, 30, and 36,000 BTU Systems Nominal Cooling BTU/h 24CL 24RL 30CLX 36CLX Cooling Only Heat Pump Cooling Only Cooling Only 24,200 24,200 30,700 33,100 ULTRA COMPACT SIZE SYSTEMS 24CL, 24RL, 30CLX, 36CLX Min.~Max. Cooling BTU/h 5,200~26,000 5,200~26,000 9,900~32,400 9,900~34,100 Nominal Heating BTU/h - 27,600 - - Min.~Max. Heating BTU/h - 4,100~36,200 - - HSPF BTU/hW - 10.0 - - SEER BTU/hW 18.0 18.0 15.0 15.
6-26-FG2000 20 pgr.qxd 4/12/06 12:49 PM Page 14 Wall Mounted Mix & Match Multi-Zone Systems DUAL, TRI AND QUAD ZONE SYSTEMS POSSIBLE COMBINATIONS Cooling Up to 16.5-SEER* Function Up to 16.5-SEER in efficiency cooling-only and heat pump systems have up to a 65% increase in efficiency over conventional 10-SEER models and feature Indoor Air Quality (IAQ) Plasma Filters, R410A refrigerant, quieter operation and increased energy efficiency and up to four zones cooled or heated by one outdoor unit.
6-26-FG2000 20 pgr.qxd 3/2/06 3:21 PM Page 15 DUAL ZONES 18RMLQ 21RMLQ 24RMLQ 27RMLQ 30RMLQ 33RMLQ 9+9 Heat Pump 12+9 Heat Pump QUAD ZONE TRI ZONES 12+12 Heat Pump 9+9+9 Heat Pump 12+9+9 Heat Pump 12+12+9 Heat Pump 36RMLQ12x3 36RMLQ 36RMLQ9x4 12+12+12 9+9+9+9 18+9+9 Heat Pump Heat Pump Heat Pump Total Min/Nom/Max Clg BTU/h 10 / 19 / 22.6k 10k / 21.5k / 26k 10k / 24k / 27.6k 11k / 27.6k / 33k 11k / 30.4k / 33.9k 11k / 33k / 34.6k 11k / 35.1k / 35.7k 11k / 35.2k / 36k 11k / 35.
6-26-FG2000 20 pgr.qxd 3/2/06 3:24 PM Page 16 Ceiling Cassette Systems SUPER ENERGY EFFICIENCIES SYSTEMS 18RCLX, 24RCLX, 36RCLX, 42RCLX UP TO 16-SEER Function Up to 16-SEER, these models provide up to 60% increase in efficiency over 10-SEER models. These models offer the ability to send up to 50% of their capacity through two branch ducts to adjacent rooms. Slender fit feature now offered on all models decreases space required above the ceiling increasing application opportunities.
6-26-FG2000 20 pgr.qxd 3/2/06 3:24 PM Page 17 18RCLX 24RCLX 36RCLX Nominal Cooling BTU/h Min.~Max. Cooling BTU/h Nominal Heating BTU/h Min.~Max. Heating BTU/h Heat Pump 42RCLX Heat Pump Heat Pump 17,800 22,200 34,100 Heat Pump 42,700 5,000~21,500 5,000~27,300 8,500~36,000 13,700~45,000 21,000 24,200 36,000 45,200 5,000~25,600 5,000~29,000 9,200~42,700 14,300~54,600 HSPF BTU/hW 8.5 8.5 8.5 8.5 SEER BTU/hW 16.0 15.0 14.0 15.0 11.1 / 10.2 10.6 / 10.2 8.1 / 9.7 9.2 / 10.
6-26-FG2000 20 pgr.qxd 3/8/06 12:22 PM Page 18 Ceiling and Universal Mounted Systems SYSTEM VERSATILITY SYSTEMS 18RULX, 24RULX, 36RSLX 18RULX 24RULX 36RSLX Nominal Cooling BTU/h Min.~Max. Cooling BTU/h Nominal Heating BTU/h Min.~Max. Heating BTU/h UP TO 16-SEER Heat Pump Heat Pump 17,800 22,200 34,100 5,000~21,600 5,000~27,300 8,500~36,000 21,500 24,000 36,500 5,000~25,600 5,000~29,000 9,200~42,700 HSPF BTU/hW 8.5 8.5 8.5 SEER BTU/hW 16.0 15.0 14.0 10.9/9.6 9.9/10.
6-26-FG2000 20 pgr.qxd 3/3/06 4:18 PM Page 19 Warning ISO Certification Always use a licensed installer or contractor to install this product. Do not ISO14001 is the standard defined by the International Organization try to install the product yourself. Improper installation can result in water or for Standardization (ISO) related to environmental management systems. refrigerant leakage, electrical shock, fire or explosion. Use only parts and Fujitsu General America, Inc.
6-26-FG2000 20 pgr.qxd 3/3/06 4:19 PM Page 20 For over 30 years, making the hottest places cool and the coolest places more comfortable. Distributed by: Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: (888) 888-3424 Local: (973) 575-0380 Fax: (973) 836-0447 Email: hvac@fujitsugeneral.com www.fujitsugeneral.com A subsidiary of Fujitsu General Limited Printed in the USA Rev.