Owner`s manual
INSTALLATION INSTRUCTIONS - Selecting the locations
10
INDOOR SECTION
• Indoor unit should only be installed indoors,
and on a sturdy wall. Installing on an external
wall, simplifies the installation significantly.
• Air inlet and outlet ports of the indoor section
at the installed position should be clear of any
obstructions.
• Location should be chosen to be at a central
location within the space for better air distribution
within the entire space.
• Choose the location away from direct sunlight.
• Choose the location to be closest possible to
the location of the outdoor section.
• Choose the location where the condensate
water can be discarded through the drain line.
• Assure the minimum shown clearances are
observed around the unit.
• Assure the unit can be easily accessed for
filter cleaning and other maintenance.
OUTDOOR SECTION
• Outdoor unit should only be installed
outdoors, and on a sturdy slab, flat roof or on
suitable brackets against an external wall.
• Air inlet and outlet ports of the outdoor section
at the installed position should be clear of any
obstructions, hedges, bushes, plants.
• Location should be at an area where the
operating noise will not disturb the neighbors.
• Choose the location away from direct sunlight.
• Choose the location away from strong winds.
• Choose the location to be closest possible to
the location of the indoor section.
• Choose the location where snow, mud or
other debris do not accumulate within the area.
• Assure the minimum shown clearances are
observed around the unit.
• Assure the unit can be easily accessed for
cleaning and other maintenance.
MAX PIPE LENGTH AND HEIGHT
• Total maximum piping length should not
exceed 50 feet straight.
• Total altitude difference between the indoor
and outdoor sections should not exceed 16 feet.
• Either the indoor or the outdoor unit can be
placed higher than another.
• Refrigerant amount must be adjusted based
on the pipe length and other factors.
Mounting Plate
Condensate water drain line
Wall Sleeve
Wrapping Tape
Interconnecting Cables
Condensate Drain Hose
6 Inches
6 Inches
6 Inches
20 Inches
12 Inches
6 Inches
12 Inches
7 Feet
< Outdoor unit above indoor unit
Indoor unit above outdoor unit >