OPERATIONS
Answering a door call
1
Press and hold for 2 seconds or more.
After approx. 2 seconds beep sounds, PTT mode is engaged.
If
is pressed briefly, PTT mode is not engaged.
2
When communicating, keep pressed. To hear the callers voice,
release
.
Status LED lights when you talk, and flashes slowly as you listen to caller
(or hear outside sounds).
NOTES:
It is not possible to switch back to hands-free mode (from PTT mode
during communication).
For loud outdoor areas, use Press-to-Talk mode (PTT)
1
Push Call button.
2
The call tone sounds, an image appears on screen.
The screen turns off after approx. 45 seconds if not answered.
3
Push , and after the beep, communicate hands-free (hands-free mode).
4
After finishing communication, push and communication
will end after the beep.
NOTES:
Communication ends automatically after approx. 1 minute.
The communication volume can be adjusted during the monitoring or
the communication by pressing
.
There are three communication volume setting to cycle through:
[
] (Minimum), [
] (Medium), and [
] (Maximum). The current
volume level is displayed on the screen and disappears in approx. 5
seconds. The default setting is [
] (Medium).
Even when the expansion monitor station has responded to a call from
the door station, the master monitor station displays the image for
approx. 45 seconds.
While either of the expansion monitor station or the master monitor
station is displaying an image, the White light LED of the door station
remains on at night.
Pushing
of the master monitor station while the expansion monitor
station is communicating with the door station results in three-way
communication.
The master monitor station and the expansion monitor station cannot call
or communicate each other.
Pushing of the master monitor station while the expansion monitor
station is communicating with the door station can display the entrance
and enable monitoring of the communication.
After 2 seconds or more