User's Manual
2029 Becker Dr
Lawrence, KS 66047
1. Technical Data
Table 1: Specifications
Notes:
● All specs above are measured under the environment of 35 °C temperature, standard atmospheric
pressure and humidity, without any Electromagnetic Interference (EMI).
● Operational Temperature Range indicates radar works properly in this range. If operating
temperature goes beyond this range, radar might not be accurate and can suffer mechanical
damage.
● Radar unit can be shipped with either CAN or UART for it’s output data protocol.
● * Operational Temperature Range is based off of the hardware’s subcomponent specifications.
Actual operational testing is still pending.
Proprietary information
Page 4
Frequency
Band
24 GHz
Bandwidth
190 MHz
Minimum
Operating
Altitude
0.5 meters
Maximum
Operating
Altitude
50 meters
Altitude
Precision
6.0cm (< 1m), 4.0cm (> 1m)
Field of View
43 ° x 30 °
Interface
UART, CAN
Update Rate
UART: 82 Hz
CAN : 86 Hz
Supply Voltage
5V~13V DC (5.5V recommended)
Power
Consumption
2W(at 5 Volts DC input)
Operational
Temperature
Range
-20 °C ~ 65 °C*
Size
108 x 79 x 20 millimeters
Weight
110 grams
Environmental
Conditions
IP67(with sealant)