User's Manual

9
f Conrm zeroing by ring at least three shots at a zeroing target.
Check points of impact to conrm accuracy and repeat above
procedure if required.
g After initial ring, ensure that the sight with mount is securely
installed on the weapon.
e Windage adjustments (See Fig. 3)
To move the point of impact to the right, turn Windage
adjustment screw (5) counter clockwise.
To move the point of impact to the left, turn Windage
adjustment screw (5) clockwise.
Elevation adjustments (See Fig. 4)
To move the point of impact up, turn Elevation adjustment
screw (4) counter clockwise.
To move the point of impact down, turn Elevation adjustment
screw (4) clockwise.
NOTE: Each click of the Adjustment screws (4) (5) corresponds to
a 13 mm movement of the point of impact at 100 meters, (3 mm at
25 meters and 26 mm at 200 meters or 0.5 in at 100 yds).
Fig. 3 Windage adjustments Fig. 4 Elevation adjustments