User's Manual

2 OPERATION UNDER NORMAL CONDITIONS
WARNING: Ensure the weapon is not loaded and the safety selector
is in the ”safe” position before attempting to install, remove or perform
maintenance.
2.1 Installing Battery
a Remove battery Cap (4) by turning it counter clockwise.
b Insert an AA-size battery with negative (-) end toward battery cap (4).
CAUTION: Check that the o-ring is in good condition and in position to
ensure there is no water leakage into the battery compartment.
c Install battery Cap (4) by turning clockwise until snug. Hand tighten only.
Using tools could damage equipment.
d Verify that red dot is present by turning the rotary switch (7) clockwise.
2.2 Lens Covers
In order to preclude the loss of the Lens Covers (8) when removed from the
optical path of the Sight, the Lens Covers should be removed downwards.
The rubber string will then attach around the Sight and mount.
2.3 Mounts and Spacers
The CompM4 and CompM4s Sights are designed for installation on rearms
which have a MIL-Std 1913 Picatinny Rail or a Weaver Rail. For complete
instructions on how to install the Sight on the weapon, consult Chapter II in
the Operating and Maintenance Manual for Aimpoint Mounts and Spacers
[13510].