User guide

LCU-ONE Analog
User Manual
Release 1.02
2
Chapter 3 – Configuration
To work properly LCU-ONE Analog needs to be configured. The configuration can be
made both using Race Studio 2 and using Lambda Configurator the free software -
included in the kit - properly designed and developed by AIM to configure this device.
5
3.1 – LCU-ONE Analog standard configuration
Configuration through Race Studio 2 (standard) is possible only if calibration curve
default points – 1.95=0.65 and 4.8=1.6 – have not been modified.
To configure LCU-ONE Analog with Race Studio Configuration follow this procedure:
run the software;
press “AIM system manager” button on the left vertical keyboard;
select the logger LCU-ONE Analog is connected to
activate “Channels” layer
select the analogue channel to set the probe on
double click on “Sensor type” column corresponding to that channel and
select “AIM Lambda LCU-ONE 1.65 – 1.6 Lambda)” option as shown here
below; click out of the cell to confirm the choice.
www.aim-sportline.com
4