Instructions
  - 11 - 
Set to Centre sets the step size equal to the centre frequency. 
Set to M1 sets the step size equal to frequency of the M1 marker. 
4.3.6 Frequency/Span > Frequency Presets 
Provides a quick method of storing and recalling frequency ranges (centre+span or 
start+stop). No other parameters are stored or recalled. 
Full Span sets the frequency range to 10MHz to 3600MHz for a PSA3605 or 
6000MHz for a PSA6005. 
Store Preset creates a pop-up menu of six preset numbers. Pressing a key in the 
pop-up stores the current frequency range into that preset position. Any existing 
frequency range will be over-written. 
Recall Preset creates a pop-up menu of six preset numbers. Pressing a key in the 
pop-up sets the frequency range that has been stored in that preset position. If 
nothing has yet been stored in that position, an error message will appear. 
Toggle Last restores the frequency range that existed prior to the last preset being 
recalled. 
4.4  Sweep/BW 
4.4.1 Sweep/BW > RBW/VBW 
Sets the Resolution Bandwidth (RBW) and Video Bandwidth (VBW) for the sweep. 
RBW Auto automatically selects an appropriate RBW for the current span. When 
selected, the word Auto appears in front of the RBW value. 
RBW Set creates a pop-up menu from which an RBW can be selected between 
300Hz and 10MHz in a 1:3:10 sequence. 
VBW Track sets the VBW to track the RBW value subject to the Track Offset. 
When selected, the word Trk appears in front of the VBW value. 
Track Offset sets the relationship between VBW and RBW for VBW Track mode. 
Positive numbers set a VBW one step higher while negative numbers set it one 
step lower. The default is zero. 
VBW Set creates a pop-up menu from which a VBW can be selected between 
300Hz and 10MHz in a 1:3:10 sequence. 
4.4.2 Sweep/BW > Sweep Time 
The normal sweep time is automatically set by the Span and the RBW and is 
displayed within the lower annotation area. Narrower RBW settings create longer 
sweep times. For each RBW, the normal sweep time is broadly proportional to the 
frequency span. The sweep time can be manually reduced in order to improve responsiveness 
at the expense of some amplitude accuracy. 
Auto selects the normal sweep time and ensures the highest degree of level 
accuracy. 
Manual Down reduces the sweep time in three steps indicated by F1 to F3. The 
maximum levels of sweep time reduction are 2, 5 or 10 but the actual reduction 
varies with span and RBW. Wide RBW sweeps will not reduce. 
Set to 
Centre 
Set to 
M1 
Freq 
Presets 
Full 
Span 
Store 
Preset 
Recall 
Preset 
Toggle 
Last 
RBW/ 
VBW 
RBW 
Auto 
RBW 
Set 
VBW 
Track 
Track 
Offset 
VBW 
Set 
RBW/ 
VBW 
Auto 
Manual 
Down 