Instructions
Table Of Contents
- Cover PSA27021302- iss 12
 - PSA2702_1302 Instruction Manual - Iss 12
- 1 Product Introduction
 - 2 Basics of Operation
 - 3 Quick Start Guide
 - 4 Operation using the Menu System
- 4.1 Setting the Frequency Range of the Sweep
 - 4.2 Sweep Time
 - 4.3 Zero Span Mode (Demodulation Mode)
 - 4.4 Setting the Sweep Mode and Sweep Bandwidth (RBW)
 - 4.5 Setting the Level Attenuator, Amplitude Scale, and Limits
 - 4.6 Controlling and Storing Traces and Images
 - 4.7 Using Measurement Markers
 - 4.8 Data Logging Functions (when fitted)
 - 4.9 Storing and Recalling Set-ups | System Settings
 - 4.10 Status Information | On-screen Help | System Utilities
 - 4.11 Using Instrument Presets | Automatic Setting
 
 - 5 File Storage for Traces, Screen Images & Set-ups
 - 6 Upgrade Option U01
 - 7 Further Notes on Operation
- 7.1 Signal Overload Levels and Indication
 - 7.2 Operation using the Hard Keys Only
 - 7.3 Setting Frequencies
 - 7.4 Measuring Relative Amplitude
 - 7.5 Triggered Operation
 - 7.6 Level Offset and Compensation Tables
 - 7.7 Limit Lines & the Limits Comparator | Creating Limit Patterns
 - 7.8 The Logging Function
 
 - 8 USB Connections | File System & Files Types
 - 9 Default Settings | Power On State | Hard Reset
 - 10 Firmware Updates | Upgrades | Maintenance
 - 11 Safety Information
 - 12 Specification
 - 13 Appendix A: Optional Accessories
 - 14 Appendix B: PSA-Manager and PSA-View Software
 - 15 Appendix C: Factory Default Settings
 - 16 Appendix D: Menu Tree Diagram
 
 - Cover PSA27021302- iss 12
 

Page 41 
7.3  Setting Frequencies 
The control screens used for setting frequencies are common to Set Centre, Set Span, Set 
Start, Set Stop, Set Step and Marker Manual Set. The following illustrated example is for Set 
Centre but is similar for all other frequency setting functions. 
pressing this key will bring up either the Set by Keypad screen or the Set by Tab/Jog 
screen depending upon which one was last used for setting that frequency 
parameter.  
7.3.1 Set by Keypad 
This control screen replaces the menu with a 0 to 9 
keypad. The frequency is entered in MHz using the 
decimal point if required (maximum resolution 
0.001MHz). Frequencies can be entered just to the 
resolution required – following digits become zeros. 
Entry errors can be corrected with the back-space 
key (). 
Pressing OK sets the entered frequency without 
leaving the control screen. The frequency value is 
cleared ready for entering a new value. 
Pressing OK & Exit sets the entered frequency and 
returns to the menu. 
Pressing Exit/Cancel returns to the menu without setting the entered frequency. 
Pressing Toggle Last returns the frequency to the value directly prior to the last frequency entry. 
Pressing Tab/Jog changes to the alternate control screen as detailed below. 
7.3.2 Set by Tab/Jog 
This control screen replaces the menu with a 
display of the existing frequency and enables it to 
be changed. 
Pressing either of  the Tab keys moves the arrows 
left or right along the digits. 
Pressing either of the Jog keys increments or 
decrements the value of that digit. 
The Jog keys auto-repeat, and the new frequency is accepted and executed after a delay of 
around two seconds. 
Pressing Exit returns to the menu. Pressing Set by Keypad changes to the alternate control 
screen as detailed above. 
Note that when Navigate Screen mode is selected, the navigator keys perform the tab/jog 
function directly - see section 7.1. 
7.3.3 Shortcuts to setting a Specific Frequency Span 
Narrower Span 
Having set a frequency span in which the signals of interest are visible, the user may wish to 
examine a specific part of the span at greater resolution. 
If the point of interest is the highest level within the current sweep, it can be moved to the centre 
of the screen from the Centre sub-group menu (Freq/Span > Centre > Set C=Pk). 
Alternatively, marker M1 can be placed at the point of interest and moved to the centre of the 
screen from the Centre sub-group menu (Freq/Span > Centre > Set C=M1). 
Set 
Centre 