User Manual
Page 14 
4.1.3  Start/Stop 
controls the start and stop frequencies for the sweep. Also sets the annotation to 
Start/Stop if it was previously Centre/Span. Creates a set of bottom-row function 
keys as follows: 
enables the start or stop frequency to be set to a specific value. The 
method for setting these is similar to that for setting the Centre frequency 
 - see section 7.2 for an illustrated description of frequency setting. 
sets the start frequency to the frequency of the M1 marker and the stop frequency to 
the frequency of the M2 marker. M1 and M2 must both be active and M2 must be at 
a higher frequency than M1. 
reverts to the start and stop frequencies that existed directly before the 
Start=M1/Stop=M2 key was pressed. 
opens a second set of actions keys: Fix Start/Fix Stop and Step Down/Step Up. 
changes the action of the Step Up/Down keys so that only the stop 
frequency or start frequency respectively is changed by the step value. 
The fixed start or stop frequency is preceded by the word Fix. Pressing 
the key again, or leaving this function-set (by pressing   or any group or sub-group 
key) will cancel the fixed start or stop frequency. 
changes the start and/or stop frequencies by the value of the step size 
(see next section). The action of the Fix Start/Fix Stop keys determines 
whether both are stepped or only one is stepped. 
Note that, if the start or stop frequency is “fixed” and the step size is set to Auto, the step size 
will change on each press of step up/down so that it is always equal to one graticule division. 
returns to the alternative set of action keys for Start-Stop. Cancels the fixed start or 
stop frequency if set. 
4.1.4  Step Size 
sets the size of frequency stepping using the Step Up/Down keys. When relevant, 
the current step size is displayed within a green box above the keys. Creates a set 
of bottom-row function keys as follows: 
enables the step size to be set to a specific value. The method for setting the step 
size is similar to that for setting the Centre frequency - see section 7.1 for an 
illustrated description of frequency setting. 
causes the step size to be automatically linked to the width of the span. Thus 
Step/Up down will cause the centre frequency to change in steps of one graticule 
division. Auto step size is indicated by the word Auto above the step size value. 
sets the step size equal to the frequency difference between the M1 and M2 
markers (if active). 
sets the step size equal to either the centre frequency or to the frequency 
of the M1 marker (if active). This can be useful for observing the 
harmonics of a fundamental frequency. 
Start 
Stop 
Set 
Start 
Set 
Stop 
Start=M1 
Stop=M2 
-more- 
1 of 2 
Fix 
Start 
Fix 
Stop 
Step 
Down 
Step 
Up 
-more- 
2 of 2 
Step 
Size 
Auto 
Span/10 
Set to 
Mdelta 
Set to 
Centre 
Set to 
M1 
Set 
Step 
 
Undo 