Operation Manual

1. To stop, gently apply a gripping pressure to both
brakes simultaneously (see fig. 13), this will slow down
and stop your Rollator.
2. The brakes on your Rollator have a park option
(see fig. 14). To operate the park option, push
downwards on both brakes simultaneously. You will feel
the brake make a very slight click. Your brakes are now
in the ‘lock’ position.
3. To unlock, simply pull up the brake again, you will
hear a slight click as the ‘park’ disengages.
OPERATING THE BRAKES
fig. 13
fig. 14
BRAKE ADJUSTMENT
Your Aidapt Rollator brake system will
require periodic adjustment.
To adjust the brakes loosen Nut B and
then screw/unscrew Nut A. When
adjusted re-tighten Nut B. If further
adjustment is required then loosen the
Locking Screw and then using a pair of
pliers pull the cable down by
approximately a millimetre. Re-tighten
Locking Screw. The brakes can then be
adjusted further by loosening Nut B and
screwing/unscrewing Nut A as before
(see fig. 15)
fig. 15