Calibrate the ow control setting. (See gure 17)
• Move the control lever to the "OFF" position.
• Slide the control bracket along the control tube until the
shut-off plate in the bottom of the hopper is closed.
• Lightly tighten the hex nuts that fasten the ow control
bracket to the control tube.
• Set the adjustable stop at "5". Pull the control lever against
the stop and verify that the shut-off plate has opened about
half way.
• If the shut-off plate does not open half way, adjust the
position of the control bracket until the shut-off plate opens
about half way and closes completely.
• Tighten the hex nuts.
17