Users Manual

ASP-MICRO USER MANUAL 15
2.2.8 DISTANCE MEASUREMENT
The device can detect the distance between the target and the observation
position.
NOTE:
When measuring the distance, keep the hand and the position steady.
Otherwise, the accuracy may be affected.
1. Hold
button to show the menu.
2. Select
menu item and press button to enter the Distance Measurement
mode.
3. Press
button to go to the target setting interface.
1) Press
or to select the target from Wolf (0.8m), Bear (3.0m),
Deer (1.2m), and Custom (1.8m).
2) Set the target and press
to confirm.
4. Align the center of top mark with the edge of target top. Press
.
The cursor blinks on the top edge of the target.
5. Align the center of bottom mark with the edge of target bottom. Press
.
The left top of the image displays the distance measurement result and the
height of the target.
NOTE:
Go to distance measurement interface, and press
to view the result of the
previous measuring target.
2.2.9 HOT TRACKING
The device can detect the highest temperature spot in the scene and mark it
on display.
1. Hold
button to show the menu.
2. Select
/ and press button to enable/disable hot spot mark
(marking the spot of highest temperature).
When the hot spot mark is enabled, the
mark displays in the spot of the
highest temperature. When the scene changes, the mark moves.
2.2.10 DEFECTIVE PIXELS CORRECTION
Defective Pixels Correction (DPC) function can correct the defective pixels on
the screen which are not performed as expected.
FIGURE 2-7. DISTANCE MEASUREMENT