User's Manual
AGM Global Vision22
2.2.8 FLAT FIELD CORRECTION
Flat Field Correction (FFC) function can correct non-uniformity of display.
1. Hold
button to show the menu.
2. Select
FFC menu item and press button to switch the FFC mode.
Auto: The clip-on performs FFC automatically when switching on or rebooting
the camera.
Manual: Press
button in live view to correct the non-uniformity of display.
External: Cover the lens cap, then press
button in live view to correct the
non-uniformity of display.
3. Hold
button to confirm the setting and exit.
2.2.9 CVBS OUTPUT
You can view the video on CVBS monitor, to get a better and clear image, more
convenient to check the detail.
1. Connect the USB-CVBS cable to USB port of thermal clip-on and to monitor’s
CVBS port.
NOTE:
USB-CVBS cable need to be purchase separately.
NOTE:
CVBS Output function doesn’t support hot plug, so please connect the cable
before powering on.
2. Hold
button to show the menu.
3. Select
CVBS
menu item and press button to turn on or turn off the CVBS
video output.
2.2.10 DEFECTIVE PIXELS CORRECTION
Defective Pixels Correction (DPC) function can correct the defective pixels on
the screen which have not performed as expected.
Before you start switch the palette to White Hot mode.
1. Hold
button to show the menu.
2. Select
DPC menu item and press button.
3. Press
, , and buttons to move the cursor to the position of dead
pixel.
4. Hold
button to correct the dead pixel.
2.2.11 AUTO POWER OFF
You can set the time for the automatic shutdown of the device as required.
1. Hold
button to show the menu of device.
2. Select
Auto Power Off menu item and press button to select OFF,
30 min or 45 min.