IMPORTANT SAFETY INFORMATION
ABOUT PROPANE (LP) GAS
A self contained LP-gas cylinder for use with this appliance must have a capacity of 20
lbs. and must be equipped with a Type 1 connector and an OPD (overfill protection
device). See Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in accordance
with the specification for LP-gas cylinders of the U.S. Department of Transportation
(DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinder, Sphere and
Tubes for the Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and
shall not be used in a building, garage or any other enclosed space.
When this appliance is not is use, the gas must be turned off at the supply
cylinder.
Storage of this appliance indoors is permissible only if the cylinder is
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the
reach of children. Disconnected cylinders must have threaded valve plugs
tightly installed and must not be stored in a building, garage or any other
enclosed areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97-2014 / CSA 2.41-2014
“ Outdoor Decorative Gas Appliances”
The gas hose is routed through a “U” bolt to prevent the hose from coming in contact
with the burner. DO NOT remove the hose from the “U” bolt. See Figure 2.
Figure 1 Figure 2
SPECIFICATIONS
INPUT 40,000 Btu/hr 30,000 Btu/hr Low fire
Propane Regulator
Pressure
11 inches water column
Natural Gas Minimum
Inlet Pressure
7 inches water column
Clearances to
combustible surfaces
Sides 24in./61cm Top: 72 in. / 183 cm
Regulator hose
pointed down