User`s guide

Test Sequencing Chapter 10
VEE User’s Guide 379
Make sure the transaction is highlighted, place the cursor on
the transaction bar, press Ctrl-K to cut the test, then press
Ctrl-Y three times to paste the test back into the Sequencer.
(You could also cut and paste using the object menus.)
The default test names will be test1x2, test1x1, and test1.
Open the three Sequence Transaction dialog boxes and
change these names to test1, test2, and test3 for clarity.
1 Select Data Continuous Real64 Slider and place it to the
left of the Sequencer. Change the name to the prompt Select
Num:, size the object to be smaller, and connect it to the
Sequencer input terminal.
You can size an object as you place it by clicking and dragging
the object corners using the left mouse button.
2 Select an AlphaNumeric display, place it below the
Sequencer, enlarge it to be wider, and connect it to the Log
output terminal on the Sequencer.
3 Save the program again as seqdat1. Select a number on
the Real64 Slider object and run seqdat1. It should look
like
Figure 209.