3 Characteristics and Specifications
Supplemental Characteristics
68 U8030A Series User’s Guide
Supplemental Characteristics
Table 3 - 3 Supplemental characteristics
Parameter U8031A/U8032A
Temperature coefficient (for 12 months)
±(% of output + offset)
• Output
• CV: (0.01% + 1 mV) / °C
• CC: (0.01% + 1 mA) / °C
• OVP, OCP
• CV: <0.05% / °C
• CC: <0.05% / °C
Output voltage overshoot
During turn-on or turn-off of AC power, if output control
is set less than 1 V.
<1 V
Voltage programming speed,
to within 1% of total excursion
30 V 60 V
Up
Full load 80 ms 200 ms
No load 80 ms 100 ms
Down
Full load 30 ms 30 ms
No load 150 ms 300 ms
Over-temperature protection Yes
Last memory setting enabled Yes
Three memory storage locations for voltage
and current settings
Yes
Erasing non-volatile memory Yes, erasable through the front panel
Rack mount capability Yes, front panel and rear have rack-mountable support