Operation and Features 2
Memory Output Operations
U8030A Series User’s Guide 49
Memory Output Operations
The Memory Output feature allows operating states from the
M1, M2, and M3 memory locations to be recalled
automatically in sequential order.
Three time intervals are programmable:
• Δt
1
— time delay between recalling M1 and recalling M2.
• Δt
2
— time delay between recalling M2 and recalling M3.
• Δt
3
— time delay between recalling M3 and recalling M1.
Enable the memory output single operation
1 Enable the memory output single operation.
• Press and hold the [Memory Output] button. The display
shows HOLd until the memory output operation is
enabled.
• The Δt annunciator turns on, and all the M1, M2, and
M3 annunciators turn on.
• The operating state from M1 memory location is
recalled immediately.
• The M1 annunciator blinks. The M2 and M3
annunciators are steadily on.
• After waiting for Δt
1
, the operating state from M2
memory location is recalled.
• The M2 annunciator blinks. The M1 and M3
annunciators are steadily on.
• After waiting for Δt
2
, the operating state from M3
memory location is recalled.
• The M3 annunciator blinks for two seconds. The M1
and M2 annunciators are steadily on.