34 U4154A Logic Analyzer Service Guide
3 Testing U4154A Performance
Table 8 54855A Oscilloscope Setup
Setup: Channel 1 Setup: Channel 2 Setup: Channel 3 Setup: Channel 4
On On Off Off
Scale: 100 mV/div Scale: 100 mV/div
Offset: 600 mV Offset: 600 mV
Skew: (Set later. See
page 39.)
Skew: 0.0 seconds
Setup: Horizontal Setup: Trigger Setup: Acquisition Setup: Display
Scale: 200 ps Mode: Edge Sampling Mode: Real Time Waveforms
Position: 0 s Source: Channel 1 Memory Depth: Automatic Connect dots: checked
Reference: Center Level: 600 mV Sampling Rate: Automatic Display Mode: Normal
Roll Mode: not selected Edge: Rising Edge Sine(x)/x Interpolation:
checked
Persistence: Minimum
Delayed: not selected Sweep: Auto Averaging: Enabled,
# of Averages: 16
Grid: On, Quantity: 1,
Intensity: as preferred
Measure: Markers
Mode: Manual placement
All else: (n/a)