Specifications
12
N9330B Handheld Cable and Antenna Tester Specifications (continued)
Input and output ports
RF test port Type N, female, 50 Ω
Maximum input without damage +25 dBm, ± 50 VDC
USB master 1 x A plug v1.1 protocol
USB slave 1 x B plug v1.1 protocol
Electromagnetic compatibility
IEC 61326-1:1997+A1 1998/EN 61326-1:1997+A1:1998
CISPR 11:1990/EN 55011 1991 Group 1 Class A
IEC 61000-4-2:1995+A1 1998/EN 61000-4-2:1995 (ESD 4kV CD, 8 kV AD)
IEC 61000-4-3 1995/EN 61000-4-3:1995 (3 V/m, 80% AM)
IEC 61000-4-4 1995/EN 61000-4-4:1995 (EFT 0.5 kV line-line, 1 kV line-earth)
IEC 61000-4-5 1995/EN 61000-4-5:1995 (Surge 0.5 kV line-line, 1 kV line-earth)
IEC 61000-4-6 1996/EN 61000-4-6:1996 (3 V, 0.15 to 80 MHz, 80% AM, power line)
IEC 61000-4-11 1994/EN 61000-4-11:1994 (Dips 1 cycle, 100%)
Canada ICES-001:1998
Australia/New Zealand AS/NZS 2064.1
Safety
IEC 61010-1 2001/EN61010-1:2001, CSA C22.2 No.61010-1:2004, UL61010-1:2004
Temperature
Operating temperature range –10°C to +50 °C (using battery)
0°C to +40 °C (using AC-DC adapter)
Battery charging temperature range 0°C to +50 °C
Storage temperature range –40°C to +70 °C
Battery storage temperature range –20°C to +70 °C
Environmental
According to Agilent Environmental Test Manual class OE, except temperature
Power supply
External DC Input +11 to +25 V DC, 40 W min.
Internal battery Rechargeable lithium-ion battery. 4 hours operating time
Dimensions
Size (W x H x D) 317 mm x 207 mm x 69 mm (12.5 in x 8.1 in x 2.7 in)
Weight Net weight: 2.6 kg (5.73 lbs)
Weight with battery: 2.9 kg (6.39 lbs)