User`s guide
Making Measurements 2
Measuring Frequency
U1273A/U1273AX User’s Guide 83
Figure 2-38 Frequency display
The frequency of the input signal is shown in the primary
display. The voltage or ampere value of the signal is shown
in the secondary display. The bar graph does not indicate
frequency but indicates the voltage or ampere value of the
input signal.
Press to cycle through the frequency, pulse width, and
duty cycle measurements.
Press for more than 1 second to exit the frequency
measurement function.
NOTE
Observe the following measurement techniques:
• If a reading shows as 0 Hz or is unstable, the input signal may be below
or near the trigger level. You can usually correct these problems by
manually selecting a lower input range, which increases the sensitivity
of the multimeter.
• If a reading seems to be a multiple of what you expect, the input signal
may be distorted. Distortion can cause multiple triggerings of the
frequency counter. Selecting a higher voltage range might solve this
problem by decreasing the sensitivity of the multimeter. In general, the
lowest frequency displayed is the correct one.
H
z
%
m
s
L
o
g
Exit
Dual