User`s guide
Table Of Contents
- Agilent U1231A, U1232A, and U1233A Handheld Digital Multimeter
- Table of Contents
- List of Figures
- List of Tables
- Introduction
- Making Measurements
- Multimeter Features
- Multimeter Setup Options
- Using the Setup Menu
- Setup Menu Summary
- Setup Menu Items
- Changing the variation count
- Enabling and changing the Smooth refresh rate
- Enabling and changing the voltage alert level
- Changing the beep frequency
- Changing the auto power-off (APO) timeout
- Changing the LCD backlight timeout
- Adjusting the LCD backlight intensity
- Enabling the LED flashlight timeout
- Adjusting the LED flashlight intensity
- Changing the minimum measurable frequency
- Changing the continuity test alerts
- Changing the power-on greeting tone
- Resetting the Setup items
- Changing the scale conversion value
- Enable the AC/DC mV measurement
- Enable open continuity test by default
- Changing the temperature unit
- Characteristics and Specifications

4 Multimeter Setup Options
Setup Menu Items
96 U1231A/U1232A/U1233A User’s Guide
Resetting the Setup items
The Setup items can be reset to their default values through
this Setup item.
Select and press to perform the reset. The
multimeter will beep once and return to the first Setup item.
Figure 4-13 Resetting the Setup items
Changing the scale conversion value
This setting is used with the Scale function (see page 76).
You can choose to set the scale conversion value from seven
different selections.
Use this Setup item to change the scale conversion value
(either 1000 A/V, 1000 °C(°F)/V, 1000 V/V, 100 A/V, 10 A/V,
1 A/V, or 0.1 A/V).
Parameter Range Default setting
rSt rES.n or rES.Y rES.n