SCPI Command Description
OUTPut
[:STATe] <Bool> [,NORelay], (@chanlist)
Enables/disables the specified output channel(s)
:COUPle
[:STATe] <Bool>
Enables/disables channel coupling for output synchronization
:CHANNel [<NR1> {,<NR1>}]
Selects which channels are coupled
:DOFFset <NRf>
Specifies a maximum delay offset to synchronize output changes
:MAX
:DOFFset?
Returns the maximum delay offset required for a mainframe
:DELay
:FALL <NRf+>, (@chanlist)
Sets the output turn-off sequence delay
:RISE <NRf+>, (@chanlist)
Sets the output turn-on sequence delay
:PMODe VOLTage | CURRent, (@chanlist)
Sets the mode for turn on/off transitions (N6761A, N6762A)
:TMODe HIGHZ | LOWZ, (@chanlist)
Specifies the turn-on/turn-off impedance (only on N678xA SMU)
:INHibit
:MODE LATChing | LIVE | OFF
Sets the remote inhibit input
:PON
:STATe RST | RCL0
Programs the power-on state
:PROTection
:CLEar (@chanlist)
Resets latched protection
:COUPle <Bool>
Enables/disables channel coupling for protection faults
:DELay <NRf+>, (@chanlist)
Sets over-current protection programming delay
:OSCillation <Bool>, (@chanlist)
Enables/disables output oscillation protection (N678xA SMU)
:WDOG
[:STATe] <Bool>
Enables/disables the I/O watchdog timer
:DELay <NRf+>
Sets the watchdog timer delay
:RELay
:POLarity NORMal | REVerse, (@chanlist)
Sets the output relay polarity (Option 760)
SENSe
:CURRent
:CCOMpensate <Bool>, (@chanlist)
Enables/disables the capacitive current compensation
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Selects the current measurement range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:ELOG
:CURRent
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the external data log current range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:FUNCtion
:CURRent <Bool>, (@chanlist)
Enables/disables external current data logging
:MINMax <Bool>, (@chanlist)
Enables/disables external min/max current data logging
:VOLTage <Bool>, (@chanlist)
Enables/disables external voltage data logging
:MINMax <Bool>, (@chanlist)
Enables/disables external min/max voltage data logging
:PERiod <NR1>, (@chanlist)
Sets the integration time of the external data logging
:VOLTage
[:DC]:RANGe
[:UPPer] <NRf+>, (@chanlist)
Sets the external data log voltage range
:AUTO <Bool>, (@chanlist)
Enables/disables measurement autoranging (N6781A, N6782A)
:FUNCtion “VOLTage” | ”CURRent” | “NONE”, (@chanlist)
Selects the measurement function (for backward compatibility)
:CURRent <Bool>, (@chanlist)
Enables/disables current measurements (replaces FUNCtion)
:VOLTage <Bool>, (@chanlist)
Enables/disables voltage measurements (replaces FUNCtion)
:INPut MAIN | AUXiliary, (@chanlist)
Selects the voltage measurement input (only on N6781A)