Specifications

Performance Verification 2
Series N6700 Service Guide 37
Test Record Form Agilent N6776A
Agilent Model N6776A Report No _______________ Date __________________
Description Model Minimum Specs. Results Maximum Specs.
Constant Voltage Tests
Voltage Programming & Readback
Minimum Voltage Vout
Voltage measured over interface
High Voltage Vout
Voltage measured over interface
0 mV
Vout 100 mV
99.8 V
Vout 200 mV
__________
__________
__________
__________
+ 200 mV
Vout + 100 mV
100.2 V
Vout + 200 mV
CV Load Effect
45 mV
__________
+ 45 mV
CV Source Effect
10 mV
__________
+ 10 mV
CV Ripple and Noise
peak-to-peak
rms
N/A
N/A
__________
__________
+ 45 mV
+ 18 mV
Transient Response
Voltage at 250 µs
1000 mV
__________
+ 1000 mV
Constant Current Tests
Current Programming & Readback
Minimum Current Iout
Current measured over interface
High Current Iout
Current measured over interface
25.5 mA
Iout 6 mA
2.9655 A
Iout 10.5 mA
__________
__________
__________
__________
+ 34.5 mA
Iout + 6 mA
3.0345 A
Iout + 10.5 mA
CC Load Effect
6 mA
__________
+ 6 mA
CC Source Effect
1 mA
__________
+ 1 mA
Test Description
N6776A Setting
Voltage Programming & Readback, Min 100 mV, 3 A
Voltage Programming & Readback, High 100 V, 3 A
CV Load Effect, Source Effect, Ripple and Noise 100 V, 3 A
Transient Response 100 V, from 1.5 A to 3 A
Current Programming & Readback, Min 4.5 mA, 100 V
Current Programming & Readback, High 3 A, 100 V
CC Load Effect, Source Effect 3 A, 100 V