Specifications
2 Performance Verification
34 Series N6700 Service Guide
Test Record Form – Agilent N6773A
Agilent Model N6773A Report No _______________ Date __________________
Description Model Minimum Specs. Results Maximum Specs.
Constant Voltage Tests
Voltage Programming & Readback
Minimum Voltage Vout
Voltage measured over interface
High Voltage Vout
Voltage measured over interface
+ 10 mV
Vout − 20 mV
19.96 V
Vout − 40 mV
__________
__________
__________
__________
+ 50 mV
Vout + 20 mV
20.04 V
Vout + 40 mV
CV Load Effect
− 13 mV
__________
+ 13 mV
CV Source Effect
− 2 mV
__________
+ 2 mV
CV Ripple and Noise
peak-to-peak
rms
N/A
N/A
__________
__________
+ 20 mV
+ 3 mV
Transient Response
Voltage at 250 µs
Voltage at 250 µs w/Option 760/761
− 300 mV
− 350 mV
__________
__________
+ 300 mV
+ 350 mV
Constant Current Tests
Current Programming & Readback
Minimum Current Iout
Current measured over interface
High Current Iout
Current measured over interface
− 30 mA
Iout − 15 mA
14.9175 A
Iout − 37.5 mA
__________
__________
__________
__________
+ 90 mA
Iout + 15 mA
15.0825 A
Iout + 37.5 mA
CC Load Effect
− 6 mA
__________
+ 6 mA
CC Source Effect
− 1 mA
__________
+ 1 mA
Test Description
N6773A Setting
Voltage Programming & Readback, Min 30 mV, 15 A
Voltage Programming & Readback, High 20 V, 15 A
CV Load Effect, Source Effect, Ripple and Noise 20 V, 15 A
Transient Response 20 V, from 7.5 A to 15 A
Current Programming & Readback, Min 30 mA, 20 V
Current Programming & Readback, High 15 A, 20 V
CC Load Effect, Source Effect 15 A, 20 V