Specifications

2 Performance Verification
30 Series N6700 Service Guide
Test Record Form Agilent N6754A and N6756A
Agilent N6754A and N6756A Report No _______________ Date __________________
Description Model Minimum Specs. Results Maximum Specs.
Constant Voltage Tests
Voltage Programming & Readback
Minimum Voltage Vout
Voltage measured over interface
High Voltage Vout
Voltage measured over interface
Both
Both
Both
Both
0 mV
Vout 25 mV
59.939 V
Vout 55 mV
__________
__________
__________
__________
+ 50 mV
Vout + 25 mV
60.061 V
Vout + 55 mV
CV Load Effect
Both
2 mV
__________
+ 2 mV
CV Source Effect
Both
1.2 mV
__________
+ 1.2 mV
CV Ripple and Noise
peak-to-peak
rms
Both
Both
N/A
N/A
__________
__________
+ 6 mV
+ 1 mV
Transient Response
Voltage at 100 µs
Voltage at 100 µs w/Option 760/761
Both
Both
90 mV
350 mV
__________
__________
+ 90 mV
+ 350 mV
Constant Current Tests
Current Programming & Readback
Minimum Current Iout
Current measured over interface
High Current Iout
Current measured over interface
Both
Both
N6754A
N6756A
N6754A
N6756A
+ 8 mA
Iout 8 mA
19.968 A
16.071 A
Iout 28 mA
Iout 25 mA
__________
__________
__________
__________
+ 32 mA
Iout + 8 mA
20.032 A
17.029 A
Iout + 28 mA
Iout + 25 mA
CC Load Effect
Both
5 mA
__________
+ 5 mA
CC Source Effect
Both
2 mA
__________
+ 2 mA
Instrument Settings
Test Description N6754A N6756A
Voltage Programming & Readback, Min Voltage 25 mV, 5 A 25 mV, 8.33 A
Voltage Programming & Readback, High Voltage 60 V, 5 A 60 V, 8.33 A
CV Load Effect, Source Effect, Ripple and Noise
60 V, 5 A
60 V, 8.33 A
Transient Response 15 V, from 10 A to 20 A 29 V, from 8.5 A to 17 A
Current Programming & Readback, Min Current 20 mA, 15 V 20 mA, 29 V
Current Programming & Readback, High Current 20 A, 15 V 17 A, 29 V
CC Load Effect, Source Effect
20 A, 15 V
17 A, 29 V