Programming instructions

Table Of Contents
Command Reference
Amplitude Modulation Subsystem ([:SOURce])
Chapter 4 231
:AM[1]|2[:DEPTh][:LINear]:TRACk
Supported PSG-A Series
[:SOURce]:AM[1]|2[:DEPTh][:LINear]:TRACk ON|OFF|1|0
[:SOURce]:AM[1]|2[:DEPTh][:LINear]:TRACk?
This command enables or disables the coupling of the AM depth values between the
paths (AM[1] and AM2).
ON (1) This choice will link the depth value of AM[1] with AM2; AM2 will
assume the AM[1] depth value. For example, if AM[1] depth is set to 15%
and AM2 is set to 11%, enabling the depth tracking will cause the AM2
depth value to change to 15%. This applies regardless of the path (AM[1]
or AM2) selected in this command
OFF (0) This choice disables the coupling and both paths will have independent
depth values.
*RST 0
Key Entry
AM Depth Couple Off On
Remarks When the depth values are coupled, a change made to one path is
applied to both.
LINear must be the current unit of measure choice for this command to
have any affect. Refer to “:AM[1]|2:TYPE” on page 229 for setting the
AM measurement unit.
Choices ON OFF 1 0