 52 Status Reporting
 Table 4-2. Bit Configurations of Status Registers
 Bit  Signal  Meaning  Bit  Signal  Meaning
 Operation Status Group
 Standard Event Status Group
 0  CAL  The interface is computing new
calibration constants.
 0  OPC  Operation complete.
 5  WTG  The interface is waiting for a trigger.  2  QYE  Query error.
 8  CV  The power module is in constant
voltage mode.
 3  DDE  Device-dependent error.
 10  CC  The power module is in constant  4  EXE  Execution error.
   current mode.  5  CME  Command error.
      7  PON  Power on.
 Questionable Status Group
 Status Byte and Service Request
Enable Registers
 0  OV  The power module overvoltage
protection circuit has tripped.
 3  QUES  Questionable status summary bit.
 1  OC  The power module overcurrent
protection circuit has tripped.
 4  MAV  Message Available summary bit.
 4  OT  The power module has an
overtemperature condition.
 5  ESB  Event Status summary bit.
 9  RI  The power module remote inhibit state
is active.
 6  MSS
 RQS
 Master Status summary bit.
 Request Service bit.
 10  UNR  The power module output is
unregulated.
 7  OPER  Operation status summary bit.
 Figure 4-1. Power Supply Status Model