Specifications
9
Page 17
安捷倫科技高頻元件量測研討會
Feb.23, 2006
Minimum Pulse Widths for Point-in-Pulse
Measurements Using Wideband Detection
No2 us600 kHz
PNA-L models
(2-port, 6, 13.5 GHz; 4-port, 20
GHz)
Yes10 us250 kHz
PNA-L models
(2-port, 20, 40, 50 GHz)
Yes50 us40 kHz
PNA models
(20, 40, 50, 67 GHz)
IF auto-gain
mode*
Minimum
pulse width
Maximum
IF bandwidth
* Note: for point-in-pulse measurements, the IF auto-gain
mode should be turned off (i.e., set IF gains manually)
Page 18
安捷倫科技高頻元件量測研討會
Feb.23, 2006
P
1
P
2
P
3
P
4
P
5
P
6
…
CW pulses
Fastest PRI/PRF for Pulse-Pulse Measurements
Using Wideband Detection
25 kHz40 us600 kHz
PNA-L models
(2-port, 6, 13.5 GHz; 4-port, 20
GHz)
12.5 kHz80 us250 kHz
PNA-L models
(2-port, 20, 40, 50 GHz)
5.9 kHz170 us40 kHz
PNA models
(20, 40, 50, 67 GHz)
Maximum
PRF
Minimum
PRI
Maximum
IF bandwidth
Conditions: point sweep; external trigger, CW
sweep; IF autogain=off
PRI