Specifications

32
Page 63
安捷倫科技高頻元件量測研討會
Feb.23, 2006
Compare Eye FP to DCA on Same Data
DCA Measurement
1G Data Rate through 20” trace
Eye Diagram FrontPanel on the DCA output
file.
[NOTE: FrontPanel data is from a single trace.
DCA measurements are averaged with 16
measurements.]
5.7/5.85.7pS5.8pSJitter rms
22.2/22.222.2pS22.2pSJitter p-p
10.01/10.2310.0710.18Eye S/N
273.9/274.9274.7mV274.7mVEye Height
386.3/389.4389mV389.4mVEye Amp
211/219215pS212pSFall Time
219/226222pS219pSRise Time
-177.5/-178.5-177.5mV-177.4mVLevel 0
211.3/213.5211.3mV212mVLevel 1
DCA
min/max
DCA typFrontPanel
[NOTE: FrontPanel results are preliminary until
ADS 2005A final release.]
Page 64
安捷倫科技高頻元件量測研討會
Feb.23, 2006
Compare Eye FP to DCA on Same Data
DCA Measurement
5G Data Rate through 20” trace
Eye Diagram FrontPanel on the DCA output file.
[NOTE: FrontPanel data is from a single trace. DCA
measurements are averaged with 16
measurements.]
12.43/12.6512.5pS12.6pSJitter rms
53.28/54.0254.02pS53.44pSJitter p-p
3.79/3.803.793.79Eye S/N
60.8/61.561mV61.3mVEye Height
293.4/293.8293.7mV293.8mVEye Amp
140.6/140.6140.6pS140.6pSFall Time
136.2/136.9136.2pS136.3pSRise Time
-136.6/-136-136mV-136mVLevel 0
156.4/157.5157.5mV157mVLevel 1
DCA min/maxDCA typFrontPanel
[NOTE: FrontPanel results are preliminary until
ADS 2005A final release.]