User manual
5-182 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
Table 5-79 Configuration: Test Condition Measurement Item
Measurement Item Description
Peak TX Power Sets a high and a low measurement limit.
The nominal limits are specified depending on the radio system and the power control
level (PWR CNTL).
You can change the nominal limits by entering temporary limits ranging from -99.9
to +99.9 dB in 0.1 steps. However, once power control level is changed after this
modification, the nominal limits are automatically set.
Burst Timing Sets a high and a low measurement limit. The allowable range is from -9.9 to +9.9
bits in 0.1 steps.
Power Ramp The test limits are automatically specified depending on the radio system selected.
Phase Error (RMS) Sets a high measurement limit for the rms over the active part of the timeslots
between 0 and 147 bits. The allowable range is from +0.0 to +99.9 in 0.1º
steps.
Phase Error (Peak) Accepts a set of a high and a low measurement limit for the peak errors over the
active part of the timeslots between 0 and 147 bits. The allowable range is from
-99.9 to +99.9 in 0.1º steps.
Frequency Error Sets a high and a low measurement limit over the active part of the timeslots. The
allowable range is from -99999 to +99999 Hz in 1 Hz step.
Sensitivity/BER Class Ib, Class II
(GSM mode)
Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
Sensitivity/FER (GSM mode) Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
RX Quality (GSM mode) Sets a high and a low measurement limit. The allowable range is 0 to 7.
RX Level (GSM mode) Sets a high and a low measurement limit. The allowable range is 0 to 63.
Sensitivity/BLER (GPRS/EGPRS
mode)
Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
Sensitivity/BER
(GPRS mode)
Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
EVM RMS Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
EVM Peak Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
EVM 95% Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
Origin Offset Spr.
(EGPRS mode)
Sets a high measurement limit. The allowable range is from 0.00 to 99.99 % in
0.01 % steps.
ORFS Mod Sets a high measurement limit. The allowable range is from -99.9 to 0.0 dBm in
0.1 dB steps.