Setting Measurement Limits for Measurement Items
The LO Limit and HI Limit values for the measurement items in
the table need to be set to execute Pass/Fail tests by Automatic
Test, Manual Test, and TX Analyzer. All measurement items can
be set with limits to execute Pass/Fail tests on the
[Configuration: Test Sequence] screen (even if some
measurement items are skipped).
The changing magnification softkey is available. Refer to
Storing
Numeric Values on page 8 and Changing Magnification Softkey on page 13.
Test Loop
(GSM mode)
Selects Test Loop of A or C.
This setting is for Manual Test (GSM mode).
Coding Scheme
(GSM/GPRS/EGPRS
mode)
Sets the Coding Scheme of PDTCH data (up and down). Selects from CS1 to CS4 and MCS1
to MCS9.
This setting is for Manual Test (GPRS/EGPRS mode).
Tes t M ode
(GPRS/EGPRS
mode)
Selects from ACK, A, B, or SRB.
ACK: Measurement of Peak TX Power, Phase Error, Frequency Error, and BLER
A: Measurement of Peak TX Power, Phase Error, and Frequency Error and EVM
B: Measurement of Peak TX Power, Phase Error, Frequency Error, and EVM. Active in
Unacknowledged Mode for UL/DL.
SRB: Measurement of Peak TX Power, Phase Error, Frequency Error, and EVM. Active in
Unacknowledged Mode for UL/DL.
This setting is for Manual Test (GPRS/EGPRS mode).
Puncturing Scheme
(EGPRS mode)
Sets the Puncturing Scheme of PDTCH data (down). Selects from P1 to P3. P3 is selected
only for MCS3, MCS4, MCS7, MCS8 and MCS9.
This setting is for Manual Test (GPRS/EGPRS mode).
Inc Redund
(EGPRS mode)
Sets On or Off of the Incremental Redundancy of re-forwarding PDTCH during Test Mode:
Ack test.
*Set the MS Power Class to the power class of the mobile phone under the test. If the mobile phone does not support the PWR CNTL,
measurement result is not displayed.
In the Automatic Test mode, the High value is used for the Burst Timing, Power Ramp, Phase Error and Frequency Error measurements.
The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on
page 13.
Table 5-78 [Configuration: Test Sequence] Screen Input Field
Input Field Description