User manual

Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-179
Table 5-78 [Configuration: Test Sequence] Screen Input Field
Input Field Description
Radio System Selects the radio system from GSM850, GSM900, DCS1800 and PCS1900. This setting is for
Manual Test, TX Analyzer, and Signal Generator.
GSM Mode Selects GSM or GPRS. This setting is for Manual Test.
Network
Sets the network parameters. Setting these parameters is required when
you test a mobile phone using a user SIM instead of a test SIM or when
you want to test network capability.
MCC: Sets Mobile Country Code. The allowable range is from 000 to 999. Set 001 for
using Test SIM supplied by Agilent Technologies.
MNC: Sets Mobile Network Code. The allowable range is from 00 to 99. Set 01 for using
Test SIM supplied by Agilent Technologies.
NCC: Sets Network Color Code. The allowable range is from 0 to 7.
LAC: Sets Location Area Code. The allowable range is from 0 to 65535.
BS_PA_MFRAMS: Sets the number of multiframes between two transmissions of the
same paging message (BS_PA_MFRMS). The allowable range is from 2 to 9.
This setting is for Automatic Test and Manual Test.
MS Power Class Sets MS power class. The allowable ranges are as follows:
GSM850: 2 to 5
GSM900: 2 to 5
DCS1800: 1 to 3
PCS1900: 1 to 3
This setting is for Automatic Test, Manual Test, and TX Analyzer.
PWR CNTL
*
(High
, Mid, Low, Manual
Tes t)
For the Automatic Test mode, sets three power control levels for the High, Mid and Low
levels.
For the Manual Test mode and TX Analyzer mode, set one power control level.
The allowable ranges for each radio system are as follows:
GSM850: 2 to 19 (+39dBm to +5dBm)
GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
The maximum value is limited by the MS Power Class setting.
Averaging
Averages respective measurement values of Peak TX Power, Phase Error and Frequency
Error.
Sets the averaging number from 2 to 99 or Off.
When this function is not required, select Off.
This setting is for Automatic Test, Manual Test, and TX Analyzer.
Also, this setting can be done on the [Manual Test] and the [TX Analyzer] screens.
Data Sets transmit data to PN9, PN9Fix or PN15.
This setting is for Automatic Test and Manual Test.