User manual

5-176 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
Configuration: Test Condition Screen
When the Test Condition softkey on the [Configuration] screen is
pressed, the [Configuration: Test Condition] screen as
Figure 5-76 for GSM mode or Figure 5-77 for GPRS mode is
displayed depending on the setting of GSM Mode setting.
Table 5-77 Configuration: Test Sequence Measurement Item
Measurement Item Description
Peak TX Power
(High, Mid, Low)
Sets execution or skip the Peak TX Power test for the High, Mid, and Low levels. The
MS power class and the power control levels for the High, Mid, and Low levels are
defined on the [Configuration: Test Condition] screen.
Burst Timing Sets execution or skip the Burst Timing test.
Power Ramp Sets execution or skip the Power Ramp test.
Phase Error (RMS, Peak) Sets execution or skip the Phase Error test.
Frequency Error Sets execution or skip the Frequency Error test.
Sensitivity (BER, FER) Sets execution or skip the Sensitivity test in BER and FER. The BS level and the
number of test frames are defined in the [Configuration: Test Condition] screen.
RX Quality Sets execution or skip the RX Quality test.
RX Level Sets execution or skip the RX Level test.