User manual
Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-175
The following measurement items need to be set to Run to
execute a Pass or Fail test or to
—— (skip) to skip a Pass/Fail
test, for each channel, respectively.
BCCH
*
Sets the broadcast control channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
TCH
*
Sets the traffic channel number for Talk step.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Detail of RF
Tes t
TCH:
Sets up to six traffic channels number.
The allowable range is as follows:
• GSM850: 128 to 251
• GSM900: 0 to 124 and 955 to 1023
• DCS1800: 512 to 885
• PCS1900: 512 to 810
RF Test item:
Sets execution or skip of Pass/Fail test. Refer to Table 5-77 for details.
ATT In and ATT Out:
Sets the insertion losses caused by the coupler or cable connecting the RF signals from/to the mobile
phone.
Depending on transmitter and receiver testing it is required to set loss values in the ATT In and ATT Out
fields as follows:
• ATT In: Sets the traffic channel attenuation values for transmitter testing. The allowable range is from
-9.9 to +9.9 dB in 0.1 dB steps.
• ATT Out: Sets the traffic channel attenuation for receiver testing. The allowable range is from -9.9
to +9.9 dB in 0.1 dB steps.
The sum of Loss setting value and ATT setting value should be greater than 0. The value less than 0 is
ineffective. Refer to Actual Input/Output Level and Correction on page 17.
Set Loss to On on the [Configuration] screen to activate the change of ATT setting.
* The toggling magnification softkey menu is displayed. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey
on page 13.
Table 5-76 [Configuration: Test Sequence] Screen Input Field
Input Field Description