User manual

5-174 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
For Location Update:
Select
Lu1 to execute MS Power On Location Update, Lu2 to
execute BS Change Location Update, or
--- to skip the step
in the test flow.
For Call and Release:
Select
BS or MS.
For other steps:
Select
Run to execute the step or —— to skip the step in the
test flow.
Screen Fields
Set the input fields of the following parameters for a new test
sequence for executing Automatic Test.
Table 5-75 Setting Combination for Automatic Test Flow
Step Sequence Test
1 Location Update Lu1/Lu2 Lu1/Lu2 Lu1/Lu2 Lu1/Lu2 —— —— —— ——
2 MS Call/BS Call Run Run —— —— Run Run —— ——
3 Talk Run/—— Run/—— —— —— Run/—— Run/—— —— ——
4 RF Test Run/—— Run/—— —— —— Run/—— Run/—— —— ——
5 MS Release/BS Release Run Run —— —— Run Run —— ——
6 MS Call/BS Call Run —— Run —— Run —— Run ——
7 MS Release/BS Release Run —— Run —— Run —— Run ——
Table 5-76 [Configuration: Test Sequence] Screen Input Field
Input Field Description
Test items Specifies execution or skip at each step. Refer to Table 5-75 on the page 174.
Radio System Selects the radio system of sequence 1 at 1:, and sequence 2 at 2: from GSM850, GSM900, DCS1800
and PCS1900.
Sequence No Sets the sequence number to set test items.
RF Output Sets the RF output for Automatic Test. Select Auto or On.
Auto: Outputs RF signal only during measurement.
On: Outputs RF signal while an [Automatic Test] screen is displayed.
Release Delay Sets the delay time from completion of the first release to start of second call in Automatic Test flow.
The allowable range is from 0 to 9 sec in 1 sec step.