Table 5-72 [TX Analyzer] Spectrum Monitor Screen Input Field
Input Field Description
Procedure Displays a list of parameter file names stored in the Tester.
If the Tester is using a parameter file, the file name is displayed in this field. If the Tester contains
parameter files, a list of those filename is displayed in this field for selection.
Radio System Selects a radio system from GSM850, GSM900, DCS1800 and PCS1900.
RFCH
*
Sets the broadcast control channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Measur Range Fixed to Auto.
Averaging Sets the averaging numbers of respective measurements.
Sets the averaging number from 2 to 99, or Off.
When this function is not required, select Off.
Modulation Selects one of the following modulation modes:
GMSK:BCCH: Sets the data of BCCH during call connecting.
GMSK:PN9: Modulates RF signal in GMSK modulation and outputs with a 9-step pseudorandom
binary sequence noise.
GMSK:PN15: Modulates RF signal in GMSK modulation and outputs with a 15-step pseudorandom
binary sequence noise.
GMSK:All0: Modulates RF signal in GMSK modulation and outputs with all-zero data.
GMSK:All1: Modulates RF signal in GMSK modulation and outputs with all-one data.
8PSK:PN9: Modulates RF signal in 8PSK modulation and outputs with 9-step pseudorandom binary
sequence noise.
8PSK:PN15: Modulates RF signal in 8PSK modulation and outputs with 15-step pseudorandom binary
sequence noise.
AM: Applies AM modulation to carrier.
PWR CNTL
*
Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
Span Sets Span to 0–400 or ±100.
0–400: f
c
to f
c
+ 400 kHz
±100: f
c