5 Screen Reference
The measurement result is displayed in the screen field.
Spectrum Monitor
The RF spectrum from fc to fc + 400 kHz relative to the RFCH
frequency is shown with the readout of the frequencies and
amplitudes at +200.0 kHz (M1) and +250.0 kHz (M2) offsets. Or,
the RF spectrum of fc 100 kHz relative to the RFCH frequency is
shown with the readout of the frequencies and amplitudes at
–67.7 kHz (M1), ±0.0 kHz (M2) and +67.7 kHz (M3) offsets.
The measured data at those frequencies are shown.
PWR CNTL
*
Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
BS Level
*
Sets the RF output level of the Tester.
The allowable range is from -110.0 to -50.0 dBm in 0.1 dB steps.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on
page 13.
Table 5-68 [TX Analyzer] EGPRS Mode ORFS Screen Input Field
Input Field Description
Table 5-69 [Manual Test] EGPRS Mode ORFS Screen Field
Screen Field Description
Modulation Displays measured Modulation value of carrier frequency at +400 kHz (Upper) and –400 kHz
(Lower).
Switching Displays measured Switching transient value of carrier frequency at +400 kHz (Upper) and –400
kHz (Lower).
Modulation Type The Modulation Type is shown.
Ref. Power The power at the time of measurement is shown.
NOTE
Installation of the Option G03 is required to display [Output RF Spectrum]