User manual

Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-157
The measurement items are shown in the screen field.
Output RF Spectrum (ORFS)
The power of the adjacent channels can be measured. The
screen of the Output RF Spectrum (ORFS) shows the
measurement result of the Modulation and Switching at the
carrier frequency rate of –400 kHz and +400 kHz.
NOTE
Installation of the Option G03 is required to display [EVM] screen.
If the measurement is not triggered, check the following items:
Power Control Level (PWR CNTL) is properly set for the mobile phone.
Midamble is properly set. If you set to None, Phase Error/ Frequency Error
measurement cannot be performed.
When Demod is set to GMSK, the displayed screen may not be the [EVM]
screen, but the [Phase Error/Frequency Error screen
Table 5-67 [TX Analyzer] EVM/Frequency Error/OOS Screen Field
Screen Field Description
EVM RMS Measured EVM (RMS) and the HI Limit are shown. The HI Limit is set on the [Configuration: Test
Condition] screen.
EVM Peak Measured EVM (Peak), the HI and the LO Limit are shown. A set of the HI and the LO Limit is set
on the [Configuration: Test Condition] screen.
EVM 95% Measured EVM (95%) and the HI Limit are shown. The HI Limit is set on the [Configuration: Test
Condition] screen.
Marker Measured Phase Error at the marker position, the HI and the LO Limit are shown. Measured data
is shown when the marker is placed on the measurement trace. The HI Limit is set on the
[Configuration: Test Condition] screen.
Freq. Err Measured Frequency Error, the HI and the LO Limit are shown. The HI and the LO Limit are set on
the [Configuration: Test Condition] screen.
OOS Measured Origin Offset, the HI and the LO Limit are shown. The HI and the LO Limit are set on
the [Configuration: Test Condition] screen.