User manual

5-148 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
RFCH
*
Sets the broadcast control channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Averaging Sets the averaging numbers of respective measurements.
Sets the averaging number from 2 to 99, or Off.
When this function is not required, select Off.
Midamble
Sets the Training Sequence Code (TSC) 0 to 7, or None for the amplitude triggering.
PWR CNTL Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
Amplitude
*
Sets the RF output level of the Signal Generator. The allowable range is from -110.0 to -20.0 dBm
in 0.1 dB steps.
Modulation Selects one of the following modulation modes:
(Installation of the Option G03 is required for 8PSK.)
GMSK:BCCH: Sets the data of BCCH during call connecting.
GMSK:PN9: Modulates RF signal in GMSK modulation and outputs with a 9-step pseudorandom binary
sequence noise.
GMSK:PN15: Modulates RF signal in GMSK modulation and outputs with a 15-step pseudorandom
binary sequence noise.
GMSK:All0: Modulates RF signal in GMSK modulation and outputs with all-zero data.
GMSK:All1: Modulates RF signal in GMSK modulation and outputs with all-one data.
8PSK:PN9: Modulates RF signal in 8PSK modulation and outputs with 9-step pseudorandom binary
sequence noise.
8PSK:PN15: Modulates RF signal in 8PSK modulation and outputs with 15-step pseudorandom binary
sequence noise.
AM: Applies AM modulation to carrier.
Offset
*
Sets frequency offset of the output signal. The allowable range is -100.0 to +100.0 kHz in 0.1 kHz
resolution.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on
page 13.
†When None is selected, Phase Error/ Frequency Error cannot be measured.
Table 5-62 [TX Analyzer] Peak TX Power/ Burst Timing/ Power Ramp Screen Input Field
Input Field Description