User manual

5-130 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
The measurement result is displayed in the screen field.
Output RF Spectrum (ORFS)
The power of the adjacent channels can be measured. The
screen of the Output RF Spectrum (ORFS) shows the
measurement result of the Modulation and Switching at the
carrier frequency rate of –400 kHz and +400 kHz.
PDTCH
*
Sets a packet data traffic channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Test Mode Selects from ACK, A, or B.
(Only ACK mode is available for measuring.)
PWR CNTL Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
Sens BS Lv
*
Sets the RF output level of the Tester for the Sensitivity test.
The allowable range is from -110.0 to -50.0 dBm in 0.1 dB steps.
BLER Frames
*
(Test Mode:
ACK)
Sets the number of test frames for BLER measurement.
The allowable range is from 1 to 13000.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on
page 13.
Table 5-54 [Manual Test] EGPRS Mode Sensitivity Screen Input Field
Input Field Description
Table 5-55 [Manual Test] EGPRS Mode Sensitivity Screen Field
Screen Field Description
BLER
(Test Mode: ACK)
Measured BLER and the HI Limit are shown. The HI Limit is set on the [Configuration: Test
Condition] screen.