User manual
5-108 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
The following measurement items are displayed in groups in the
table. When a group of measurement items is selected with the
CURSOR CONTROL knob, the Graph/Value screen for each
group is displayed.
Inc Redund Sets On or Off of the Incremental Redundancy of re-forwarding PDTCH during Test Mode: Ack test.
Averaging Displays the average value of Peak TX Power, Phase Error, and Frequency Error. Sets the averaging
number from 2 to 200, or Off. When this function is not required, select Off.
PWR CNTL Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
BS Level
*
Sets the RF output level of the Tester, ranging from -110.0 to -50.0 dBm in 0.1 dB step. The
default value is set on the [Configuration: Test Condition] screen.
Slot Config Selects 1×1, 2× 1, 2×2, 3×1, 3×2, or 4×1
Measur Slot When the Slot Config is set to 2×2 or 3×2, this field becomes a settable field.
Selects measurement slot from 2 to 4 depending on the setting of the Slot Config.
Test Mode Selects from ACK, A, or B.
ACK: Measurement of Peak TX Power, Phase Error, Frequency Error, and BLER
A: Measurement of Peak TX Power, Phase Error, and Frequency Error
B: Measurement of Peak TX Power, Phase Error, Frequency Error and BER. Active in Unacknowledged
Mode for UL/DL.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on
page 13.
Table 5-43 [Manual Test: Stand-by] EGPRS Mode Screen Input Field
Input Field Description
Table 5-44 Manual Test EGPRS Mode Measurement Item
Measurement Item Description
Peak TX Power
Burst Timing
Power Ramp
Measurement results of Peak TX Power, Burst Timing and Power Ramp are shown.
When this field is selected, the Graph/Value screen for Peak TX Power/ Burst Timing/ Power
Ramp is displayed with measurement results on text and graph display. If the marker function is
active, the Power Ramp value is displayed according to the marker position.
Phase Error (RMS)
Phase Error (Peak)
Frequency Error
Measurement results of Phase Error and Frequency Error are shown.
When this field is selected, the Graph/Value screen for Phase Error/ Frequency Error is displayed
with measurement results on text and graph display.