User manual
Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-99
•This softkey is effective only for changing
the trigger mode on the [Stand-by] screen.
• Trigger: Starts single measurement. This softkey is inactivated
on the [Stand-by] screen.
• Return: Returns to the previous screen.
Screen Field
Set the input fields of the following parameters to execute a new
test.
Table 5-38 [Manual Test] GPRS Mode Sensitivity Screen Input Field
Input Field Description
Procedure Displays a list of parameter file names stored in the Tester.
Select a file to recall for a test.
If the Tester is using a parameter file, the file name is displayed in this field. If the Tester contains
parameter files, a list of those filename is displayed in this field for selection.
This field cannot be changed on a [Measuring] screen.
Radio System Selects a radio system from GSM850, GSM900, DCS1800 and PCS1900.
This field cannot be changed on the [Measuring] screen.
BCCH
*
Sets the broadcast control channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
This field cannot be changed on the [Measuring] screen.
PDTCH
*
Sets a packet data traffic channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Test Mode Selects from ACK, A, or B.
ACK: Measurement of Peak TX Power, Phase Error, Frequency Error, and BLER
A: Measurement of Peak TX Power, Phase Error, and Frequency Error
B: Measurement of Peak TX Power, Phase Error, and Frequency Error. Active in Unacknowledged Mode
for UL/DL.