User manual
Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-85
Softkey Menu 2
• Print Screen: Prints a hardcopy of the screen or saves a graphic
file of the screen in a USB memory device
depending on the setting of the Printer input
field on the [Configuration] screen.
• Spectrum Monitor: Displays the Spectrum Monitor screen.
• More (2 of 2): Returns to the softkey menu 1.
Screen Field
The following input field can be changed on the [Measuring]
screen. Change the input fields according to Table 5-32.
Table 5-32 [Manual Test: Measuring] GPRS Mode Screen Input Field
Input Field Description
Measuring
mode
Sets whether or not to execute test items or each group of test items. Select On or Off.
• Peak TX Power, Burst Timing, Power Ramp
• Phase Error (RMS), Phase Error (Peak), Frequency Error
• Sensitivity/BLER
PDTCH
*
Sets a packet data traffic channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Coding
Scheme
Sets the Coding Scheme of PDTCH data (up and down). Selects from CS1 to CS4.
Attach: Up/Down CS1: fixed
Averaging Displays the average value of Peak TX Power, Phase Error, and Frequency Error. Sets the averaging
number from 2 to 200, or Off. When this function is not required, select Off.
PWR CNTL Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
BS Level
*
Sets the RF output level of the Tester, ranging from -110.0 to -50.0 dBm in 0.1 dB step. The
default value is set on the [Configuration: Test Condition] screen.
Slot Config Selects 1×1, 2× 1, 2×2, 3×1, 3×2, or 4×1