User manual
Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-67
Screen Field
Set the input fields of the following parameters to execute a new
test.
The measurement items are shown in the screen field.
Table 5-20 [Manual Test] GSM Mode Phase Error/Frequency Error Input Field
Input Field Description
Procedure Displays a list of parameter file names stored in the Tester.
If the Tester is using a parameter file, the file name is displayed in this field. If the Tester contains
parameter files, a list of those filename is displayed in this field for selection.
This field cannot be changed on the [Measuring] screen.
Radio System Selects a radio system from GSM850, GSM900, DCS1800 or PCS1900. This field cannot be changed on
the [Measuring] screen.
BCCH
*
Sets the broadcast control channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
This field cannot be changed on the [Measuring] screen.
TCH
*
Sets a traffic channel number.
The allowable range is as follows:
GSM850: 128 to 251
GSM900: 0 to 124 and 955 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
PWR CNTL Sets one of the factors defined for Power Control Levels according to the Radio System. The allowable
range is as follows:
GSM850, GSM900: 2 to 19 (+39dBm to +5dBm)
DCS1800: 29 to 15 (+36dBm to 0dBm)
PCS1900: 30 to 15 (+33dBm to 0dBm)
Set the MS Power Class on the [Configuration: Test Condition] screen for the power class of the mobile
phone. If the mobile phone does not support the power control function, measurement result is not
displayed.
BS Level
*
Sets the RF output level of the Tester, ranging from -110.0 to -50.0 dBm in 0.1 dB step. The
default value is set on the [Configuration: Test Condition] screen.
Averaging Sets the averaging number from 2 to 99 or Off. When this function is not required, select Off.
* The changing magnification softkey is available. Refer to Storing Numeric Values on page 8 and Changing Magnification Softkey on