User manual

5-38 N9360A Multi UE Tester GSM User Manual
5 Screen Reference
Softkey Menu Field
Softkey Menu
Print Screen: Prints a hardcopy of the screen or saves a graphic
file of the screen in a USB memory device
depending on the setting of the Printer input
field on the [Configuration] screen.
Return: Returns to the previous screen.
Screen Field
The measurement results are shown in the screen field.
Burst Timing/ Power Ramp
This function measures and analyzes the power burst timing
and the amplitude envelope in the timeslots of the RF burst
signal.
Readout function is available for the Power Ramp measurement.
In this function, that data is shown when the marker is placed
at any point of the Power Ramp measured trace. The measured
data for Burst Timing and Power Ramp are shown as
Figure 5-25.
If the measured data exceeds the limits in the graph, one or
more white triangle markers indicate the failed position at the
top of the graph frame.
Any data indicating a failure is highlighted.
Table 5-9 [Automatic Test] Peak TX Power Screen Field
Screen Field Description
High Measured Peak TX Power of PWR CNTL at high range, the Hi and the LO Limit are shown. The HI and
the LO Limit are set on the [Configuration: Test Condition] screen.
Mid Measured Peak TX Power of PWR CNTL at middle range, the HI and the LO Limit are shown. The HI and
the LO Limit are set on the [Configuration: Test Condition] screen.
Low Measured Peak TX Power of PWR CNTL at low range, the HI and the LO Limit are shown. The HI and the
LO Limit are set on the [Configuration: Test Condition] screen.