User manual

Screen Reference 5
N9360A Multi UE Tester GSM User Manual 5-21
The Radio System(s) (GSM850, GSM900, DCS1800, PCS1900) is
or are shown.
If some test items in the signaling step is set to be skipped on
the [Configuration: Test Sequence] screen, — is shown at the
corresponding steps in the test result table.
If some measurement items are set to be skipped on the
[Configuration: Test Sequence] screen, — is shown at those item
cells in the measurement result field.
RF On indicator is displayed at the lower-left corner of the screen
only when the RF signal from the Tester is presented at the RF
In/Out connector.
The information from the mobile phone as Table 5-5 is displayed
in the screen field.
Message Field
The following message is displayed in the message field on the
[Stand-by] screen:
Press {Start} to begin a test.
RX Quality Measures and analyzes the received signal quality with the mobile phone.
RX Level Measures and analyzes the received signal level with the mobile phone.
Table 5-4 Automatic Test Measurement Item
Measurement Item Description
Table 5-5 [Automatic Test: Stand-by] Screen Mobile Phone Information
Item Information Description
IMSI Displays the default value of International Mobile Subscriber Identity. The default value is
001012345678901.
IMEI This field remains blank at this state.
Caller ID Displays addresser number sent from the Tester at BS Call execution. The set value is displayed
at this state.
Dialed No. This field remains blank at this state.
Power Class This field remains blank at this state.
GSM Version This field remains blank at this state.
SIG-PTN Displays signaling pattern. The value set in the [Condition: Test Condition] screen is inserted.