User manual
4-64 N9360A Multi UE Tester CDMA2000 User Manual
4 Operating Procedure
Handoff
Softer Handoff
1 Follow the process of step 1 to step 10 of Test i ng a D ual Ba nd
Mobile Phone by Manual Test (1xEV-DO Mode) and set the mobile
phone to call connection status.
2 Press More (1 of 3) and Softer Handoff softkeys to start Softer
handoff. The Softer Handoff step is highlighted. When the
handoff is completed, P is shown at the Softer Handoff step.
3 Release the call with the following operation.
• Press the Connection Close, More (1 of 3) and Session Close
softkeys.
Hard Handoff
1 Follow the process of step 1 to step 10 of Test i ng a D ual Ba nd
Mobile Phone by Manual Test (1xEV-DO Mode) and set the mobile
phone to call connection status.
2 Change the channel with the following operation.
• Move the cursor to RFCH input field and press the
CURSOR CONTROL knob.
• Rotate the CURSOR CONTROL knob to select the channel
for handoff and press the CURSOR CONTROL knob again.
When the channel in the same band is selected, the
Channel Change step is highlighted. When the channel in
the different band is selected, Band Change step is
highlighted and the channel is changed to the selected
one.
• When handoff is completed, P is shown at the Channel
Change or Band Change step.
3 Release the call with the following operation.
• BS release: Press the Connection Close, More (1 of 3) and
Session Close softkeys.