User manual

Operating Procedure 4
N9360A Multi UE Tester CDMA2000 User Manual 4-23
3
Set the Loss field to On with the CURSOR CONTROL knob.
4 Enter the appropriate loss values, depending on the band, in
the
RF In and RF Out fields with the CURSOR CONTROL
knob. These loss values are used all through the test flow.
5 Press the Return softkey to return to the [Initial] screen.
Entering Channel Attenuations on the Configuration: Test
Sequence Screen
This section describes correction for RF test results in
Automatic Test. Each channel (RFCH) path loss value can be set
on the [Configuration: Test Sequence] screen. This is the RF test
correction function in addition to the loss function in the
[Configuration: Test Condition (Loss)] screen.
In addition to entering the loss values on the [Configuration:
Test Condition (Loss)] screen, you can also enter the
attenuation values to be used to correct the RF test results with
these values at each traffic channel in the Automatic Test mode.
Determine and enter the appropriate attenuation values at each
traffic channel with the following procedure, caused by the
antenna coupler, RF cable or shield case to connect the mobile
phone to the Tester.
1 Press the CDMA2000 softkey on the [Top Menu] screen to
activate cdma2000 system. Refer to Selection of System on
page 4-14 for detail.
2 Press the Config softkey on the [Initial] screen, and then the
Tes t Sequence softkey to display the [Configuration: Test
Sequence] screen.